What does hot sensor closed mean for Zip Water System?
- KKathy FlemingSep 5, 2025
Hot sensor closed indicates an internal fault. Call Zip Service.
What does hot sensor closed mean for Zip Water System?
Hot sensor closed indicates an internal fault. Call Zip Service.
What does hot sensor open mean for Zip HydroTap G5 Water System?
Hot sensor open indicates an internal fault. Call Zip Service.
What to do if there is a water leak in my Zip Water System?
If you notice a water leak, immediately turn off the mains water supply. You may also need to call for service.
What causes an interface fault in Zip HydroTap G5 Water System?
An interface fault is due to an internal fault. Call Zip Service.
What to do if UV is Not Present in my Zip HydroTap G5 Water System?
If UV is not present, check that the UV-C Module USB cable is correctly plugged into the HydroTap.
What to do if there is UV Over Temp in my Zip HydroTap G5 Water System?
If there is a UV Over Temp, verify that water is flowing through the UV-C Module when attempting to dispense.
What to do if there is UV Under Current in my Zip Water System?
If there is a UV Under Current, check the power supply is correctly plugged in and turned on. Turn the HydroTap off and then on.
What causes condenser over temperature in my Zip HydroTap G5?
Condenser over temperature can be caused by a blocked air filter. Remove the blockage and clean the filter.
How to reset boil dry protection on my Zip HydroTap G5 Water System?
If the boil dry protection safety is activated, turn the power OFF and then ON to reset it.
What causes a compressor over-run in my Zip HydroTap G5?
A compressor overrun can happen if the compressor is too hot. Check the ventilation.
Model | HydroTap G5 |
---|---|
Category | Water System |
Filtered Water | Yes |
Energy Efficiency | Highly efficient with Power-Pulse technology |
Filtration | 0.2 micron filtration system |
Touchscreen Control | Yes |
Touch-Free Wave Sensor | Optional |
Finish Options | Chrome, Matte Black, Brushed Nickel, Rose Gold |
Product Type | Boiling, Chilled, Filtered Water System |
Water Options | Boiling, Chilled |
Dimensions | Varies by model |
Weight | Varies by model |
Power Supply | 220-240V |
Explains the meaning of warning and information symbols used in the manual.
Provides essential preliminary instructions and precautions before operating the unit.
Details how to operate the Classic model HydroTap, including controls and lights.
Explains the operation of the Touch-Free Wave model, including sensors and dispense options.
Describes the controls and operation for HydroTap Mixer taps.
Guide on using the Command Centre's touch screen interface for system interaction.
Explains the status screens displayed on the HydroTap home screen.
Details how to navigate through the main menu options for settings and features.
Configuration options for general system parameters like language and date/time.
Access to various system configurations including filter, temperature, and dispense settings.
Features and settings related to system safety and access security.
Options for configuring energy saving modes like sleep and timers.
Step-by-step guide for replacing the internal water filter cartridge.
Instructions for cleaning and maintaining the air inlet filter.
Guidelines for cleaning the external surfaces and specific tap types.
Procedure for replacing the UV-C module and associated hose.
Instructions for replacing the safety solenoid, recommended for qualified personnel.
Guidance on replacing the chilled water hose and tap tube.
Overview of the in-field sanitisation process and required equipment.
Steps for preparing the system and connecting the sanitisation kit components.
Procedures for sanitising the system, testing, and flushing.