ES-2024A User’s Guide
Chapter 4 The Web Configurator 45
To upload the factory-default configuration file, do the following:
1 Connect to the console port using a computer with terminal emulation software. See
Section 3.1.1 on page 33 for details.
2 Disconnect and reconnect the switch’s power to begin a session. When you reconnect the
switch’s power, you will see the initial screen.
3 When you see the message “
Press any key to enter Debug Mode within 3
seconds ...
” press any key to enter debug mode.
4 Type
atlc after the “Enter Debug Mode” message.
5 Wait for the “
Starting XMODEM upload” message before activating XMODEM
upload on your terminal.
6 After the factory-default configuration file upload, type
atgo to restart the switch.
Figure 18 Resetting the Switch: Via the Console Port
The switch is now reinitialized with the factory-default configuration file including the default
password of “1234”.
4.6 Logging Out of the Web Configurator
Click Logout in a screen to exit the web configurator. You have to log in with your password
again after you log out. This is recommended after you finish a management session both for
security reasons and so as you don’t lock out other switch administrators.
Bootbase Version: V1.0 | 04/25/2003 10:01:06
RAM: Size = 32768 Kbytes
FLASH: Intel 32M
ZyNOS Version: V3.50(DU.0)| 07/11/2003 18:00:29
Press any key to enter debug mode within 3 seconds.
....................
Enter Debug Mode
ES-2024A> atlc
Starting XMODEM upload (CRC mode)....
CCCCCCCCCCCCCCCC
Total 262144 bytes received.
Erasing..
................................................................
OK
ES-2024A> atgo