ES-2024A User’s Guide
64 Chapter 7 Basic Setting
Flow Control A concentration of traffic on a port decreases port bandwidth and overflows buffer
memory causing packet discards and frame losses. Flow Control is used to regulate
transmission of signals to match the bandwidth of the receiving port.
The switch uses IEEE802.3x flow control in full duplex mode and backpressure flow
control in half duplex mode.
IEEE802.3x flow control is used in full duplex mode to send a pause signal to the
sending port, causing it to temporarily stop sending signals when the receiving port
memory buffers fill.
Back Pressure flow control is typically used in half duplex mode to send a "collision"
signal to the sending port (mimicking a state of packet collision) causing the sending
port to temporarily stop sending signals and resend later. Select Flow Control to
enable it.
802.1P Priority This priority value is added to incoming frames without a (802.1p) priority queue tag.
See Priority Queue Assignment in Table 10 on page 59 for more information.
Apply Click Apply to save the settings.
Cancel Click Cancel to reset the fields to your previous configuration.
Table 12 Port Setup (continued)
LABEL DESCRIPTION