Table 1. Power Consumption for Device Versions
State Part Nos.
916112/9161121
Part Nos.
916114/9161141
Part Nos.
916115/9161151
Part Nos.
916116/9161161
At relax 1.6 W 1.5 W 1.5 W 1.5 W
LED –
white strip
100 %
0.12 W 0.12 W 0.12 W 0.12 W
LED –
green strip
100 %
0.15 W 0.15 W 0.15 W 0.15 W
LED – red
strip 100 %
0.20 W 0.20 W 0.20 W 0.20 W
LED –
Bluetooth
100 %
0.06 W
LED – key-
pad back-
light 100 %
0.15 W
Relay at
standard
room tem-
perature
mode
0.14 W 0.14 W 0.14 W 0.14 W
OUT1 at
maximum
possible
load
6 W 6 W 6 W 6 W
Audio 0.7 W 0.7 W 0.7 W 0.7 W
Overvoltage Protection
The 2N device cables have to be protected against atmospheric overvoltage caused by external causes
(lightning, e.g.). A surge can damage a device installed outside/inside the building if the wires are unprotec-
ted.
Therefore, we recommend that additional overvoltage protectors (OVP) be installed on the outer walls or
roof for all the wires leading outside the building. Keep the following instructions while installing overvoltage
protectors:
Installation