Restart Using Web Configuration Interface,
You can restart the device via the web configuration interface. Refer to Web Configuration Interface Login (p.
38) for login details. Restart the device in System > Maintenance > System using Restart .
Factory Default Reset
Follow the instructions below 2N Access Unit M to reset the factory default values:
Factory Default Reset
1. Press and hold the RESET button.
2. Wait until the red and green LEDs go on simultaneously on the device and the acoustic signal can be
heard (approx. 15–35 s).
3. Wait until the red LED goes off and the acoustic signal can be heard (approx. for another 3 s).
4. Wait until the green LED goes off and the red LED goes on again and the acoustic signal can be heard
(approx. for another 3 s).
5. Wait until the red LED goes off and the acoustic signal can be heard (approx. for another 3 s).
6. Release the RESET button.
Factory Default Reset
Located among the main unit connectors, the CONTROL button helps you reset the factory default values.
1. Disconnect the device from the power supply.
2. Press and hold the CONTROL button.
3. Connect the device to the power supply.
4. Keep holding the button for a few seconds and then release it.
CAUTION
In case the factory default values are reset on the device with a firmware version 2.18 or
higher, it is necessary to reprogram the 2N Security Relay using the instructions given in
Security Relay.