2N TELEKOMUNIKACE a.s., www.2n.cz 100/104
Calling to Dispatching Office in Case of Unauthorised Door Opening with Service Code
Blocking Option
Specification
Call the selected telephone number whenever the tamper switch gets disconnected
(device opened). Enable blocking and re-enable numeric code alarm entered from the
intercom keypad.
Block diagram
The rising edge on the tamper input (1: Event.InputChanged) initiates calling to the
defined telephone number (5: Action.BeginCall) in case the defined condition is met.
The condition (4: Condition.FlipFlopRS) is validated by the intercom restart or
entering the selected code (2: Condition.CodeEntered) on the numeric keypad. If
another code is entered (3: Condition.CodeEntered), the condition will be invalid.
Intercom settings
1: Event.InputChanged: Input=tamper; Edge=rising
2: Event.CodeEntered: Code=164575
3: Event.CodeEntered: Code=111
4: Condition.FlipFlopRS: SetEvent=3; ResetEvent=2; ResetValue=1
5: Action.BeginCall: Number=1111; Event=1; Condition=4