Device Restart
Press the RESET button shortly (< 1 s) to restart the system without changing configuration.
Available Outputs
Location Name Description
Main Unit Relay
1
Passive switch:NO/NC contact, up to 30 V / 1 A AC/DC. Used for
connection of non-critical devices only (lights, e.g.).
Outpu
t 1
Active switch output:8 up to 12 V DCdepending on power
supply (PoE: 10 V; adaptor: power supply voltage minus 2 V),
max. 600 mA
Caution
In case of resetting the factory default settings on a device with a version of
firmware 2.18 or higher it is necessary to reprogram the
2N
®
Security Relay using the instructions from section 2.4.
Note
The time interval between the short press of RESET and reconnection after restart
is 26 s for 2N
®
IP Solo.