Index
256 3ware Serial ATA RAID Controller User Guide
Drive removed (0019) 231
Drive timeout detected (0009) 229
Flash file system error detected (003F) 237
Flash file system repaired (0040) 237
Incomplete unit detected (0006) 228
Initialize completed (0007) 228
Initialize failed (000E) 230
Initialize paused (003C) 237
Initialize started (000C) 230
Migration completed (0035) 235
Migration failed (0034) 235
Migration paused (003E) 237
Migration started (0033) 235
Primary DCB read error occurred (0042) 238
Rebuild completed (0005) 228
Rebuild failed (0004) 227
Rebuild paused (003B) 236
Rebuild started (000B) 229
Replacement drive capacity too small (002E) 234
Sector repair completed (0023) 232
SO-DIMM not compatible (0037) 236
SO-DIMM not detected (0038) 236
Source drive ECC error overwritten(002C) 234
Source drive error occurred(002D) 234
Spare capacity too small for some units (0032) 235
Unclean shutdown detected (0008) 228
Unit deleted (000D) 230
Unit inoperable (001E) 231
Unit number assignments lost (0041) 237
Unit Operational (001F) 231
Upgrade UDMA mode (0022) 232
Verify completed(002B) 234
Verify failed (002A) 234
Verify fixed data/parity mismatch (0036) 236
Verify not started, unit never initialized (002F) 235
Verify paused (003D) 237
Verify started (0029) 233
AEN messages 143, 212, 224
alarms 143
alert utility (WinAVAlarm) 144
viewing 143
Alarms page, 3DM 212
alert utility (WinAVAlarm) 144
arrays 4
array roaming 4, 128, 131
definition 244
definition 244
moving from one controller to another 131
removing in 3DM 128
asterisk next to unit 193, 194
Auto Rebuild policy 15, 87
setting 90, 200
Auto Verify policy for units 198
setting (3DM) 114
auto-carving 91
auto-carving policy 87
auto-carving policy
setting
200
available drives, 3DM 210
B
background initialization after power failure
151
background tasks
background rebuild rate (definition)
244
background task rate 198
background task rate, setting 160
definition 14
initialization 148
overview 147
prioritizing 161
rebuilding a unit 155
scheduling 161
verification 151
Backup DCB read error detected (0043) 238
Battery capacity is below error level (0059) 241
Battery capacity is below warning level (0058) 241
Battery capacity test completed (0050) 240
Battery capacity test is overdue (0053) 241
Battery capacity test started (004E) 240
Battery charging completed (0056) 241
Battery charging fault (0057) 241
Battery charging started (0055) 241
Battery health check completed (0052) 241
Battery health check failed (005D) 242
Battery health check started (0051) 240
Battery is not present (005B) 242
Battery is present (005A) 241
Battery is weak (005C) 242
Battery temperature is high (004B) 239
Battery temperature is low (004A) 239
Battery temperature is normal (0049) 239
Battery temperature is too high (004D) 240
Battery temperature is too low (004C) 239
Battery voltage is high (0046) 238
Battery voltage is low (0045) 238
Battery voltage is normal (0044) 238
Battery voltage is too high (0048) 239
Battery voltage is too low (0047) 239
BBU
Battery Backup Information page
213
testing battery capacity 187
viewing battery information 186
BIOS
showing version 191
BIOS Manager, using 57
blinking LEDs (drive locate) 166, 193, 196, 216
Boot volume size
definition 244
boot volume size, specifying 99
bootable unit, specifying 60

Table of Contents

Related product manuals