36
9902 = 1 1
Open
Closed
9902 = 12
Open
Closed
1
+24 Volt Common
1
+24 Volt Common
2
Stop
Run Forward
2
Stop
Run Forward
3
Stop
Run Reverse
3
Stop
Run Reverse
4
Selected Speed ref
Preset Speed ref
4
T4
T6
T10
Preset
5
+10 Volt
5
6
Analog Input 1
6
Open
Open
Open
1202
7
0 Volts
7
Closed
Open
Open
1203
8
8
Open
Closed
Open
1204
9
0 Volts
9
Closed
Closed
Open
1205
10
Preset Speed 1(1202)
Preset Speed 2(1203)
(1203(
10
or
ma
l
Op
er
ati
on
11
11
12
Safe Inhibit
Normal Operation
12
Safe Inhibit
Normal Operation
13
Safe Inhibit
Normal Operation
13
Safe Inhibit
Normal Operation
9902 = 13
Open
Closed
9902 = 14
Open
Closed
1
+24 Volt Common
1
+24 Volt Common
2
Stop
Run Forward
2
Stop
Run Forward
3
Stop
Run Reverse
3
Stop
Run Reverse
4
Selected Speed ref
Preset Speed 1 (1202)
4
Selected Speed ref
Preset Speed 1 (1202)
5
+10 Volt
5
+10 Volt
6
Analog Input 1
6
Analog Input 1
7
0 Volts
7
0 Volts
8
8
9
0 Volts
9
10
Analog input 2 (E.g. Torque Reference)
10
or
m
al
O
pe
ra
ti
on
Decel ramp 1 (2203)
Decel ramp 2 (2206)
11
11
12
Safe Inhibit
Normal Operation
12
Safe Inhibit
Normal Operation
13
Safe Inhibit
Normal Operation
13
Safe Inhibit
Normal Operation
9902 = 15
Open
Closed
9902 = 16
Open
Closed
1
+24 Volt Common
1
+24 Volt Common
2
Stop
Run Forward
2
Stop
Run Forward
3
Stop
Run Reverse
3
Stop
Run Reverse
4
Selected Speed ref
Analog input 2 speed ref
4
Selected Speed ref
Preset Speed 1 (1202)
5
+10 Volt
5
+10 Volt
6
Analog Input 1
6
Analog Input 1
7
0 Volts
7
0 Volts
8
8
9
0 Volts
9
0 Volts
10
Analog input 2
10
or
ma
l
Op
er
ati
on
External Trip (“F0014”)
11
11
12
Safe Inhibit
Normal Operation
12
Safe Inhibit
Normal Operation
13
Safe Inhibit
Normal Operation
13
Safe Inhibit
Normal Operation