136 Option
Remote connectivity
Contents of this chapter
This chapter describes the installation and commissioning of remote service products. For
the drives with software version MHDRE v2.04.0.1 or higher, remote connection via NETA-
21 is possible.
Make the drive ready
Hardware connection
Step4 Stop set DI1=0
60.15 Force follower = True
19.11 Ext1/Ext2 selection =
EXT2
19.14 Ext2 control mode =
Speed
60.15 Force master = True
19.11 Ext1/Ext2 selection =
EXT1
19.12 Ext1 control mode =
Speed
60.15 Force follower = True
19.11 Ext1/Ext2 selection =
EXT2
19.14 Ext2 control mode =
Torque
Step5 BCU1 is follower
3.13 M/F or D2D ref 1 = 200
3.14 M/F or D2D ref 2 = 15
1.1 Motor speed used = 200
BCU2 is master
Start DI1=1, give load 15%
1.1 Motor speed used = 200
1.10 Motor torque = 15%
BCU3 is follower
3.13 M/F or D2D ref 1 = 200
3.14 M/F or D2D ref 2 = 15
1.10 Motor torque = 15%
BCU1: BCU2: BCU3: