Connectors X30 and X55
Connector X30
Description
+C183: Heating element N (230 V AC or 115 V AC)9
+C183: Heating element L (230 V AC or 115 V AC)8
Not in use7
TP2, thermal cutoff circuit6
TP1, thermal cutoff circuit5
Not in use4
Not in use3
+C188: DOL fan N (230 V AC or option +G304: 115 V AC)2
+C188: DOL fan L (230 V AC or option +G304: 115 V AC)1
Connector X55
Note:
Connections of the connector X55 are ready-made at the factory.
Description
+C183: Heating element N (230 V AC or 115 V AC)4
+C183: Heating element L (230 V AC or 115 V AC)3
+C188: DOL fan N (230 V AC or option +G304: 115 V AC)2
+C188: DOL fan L (230 V AC or option +G304: 115 V AC)1
38 Operation principle and hardware description