DCS500 Pin and Parameter list
A 47
DECEL2
Parameter of RAMP GENERATOR-function block. ( S4/16 )
The time in which the drive will decelerate from nominal speed to zero speed.
1712 FB_P: I2 SC: 0.1 HL: 30000 LL: 1 D: 100 U: s
SMOOTH2
Parameter of RAMP GENERATOR-function block. ( S4/16 )
The speed ramp output softening time (S-RAMP function).
The total time how long the softening function will last.
1713 FB_P: I2 SC: 1 HL: 20000 LL: 0 D: 0 U: ms
EMESTOP_RAMP
Parameter of RAMP GENERATOR-function block. ( S4/16 )
The time in which the drive will decelerate from nominal speed to zero speed in
emergency stop situation.
1714 FB_P: I2 SC: 0.1 HL: 30000 LL: 1 D: 200 U: s
SPEEDMAX
Parameter of RAMP GENERATOR-function block. ( S4/16 )
Positive limit for speed reference.
1715 FB_P: I2 SC: SPEED HL: 30000 LL: 0 D: 20000 U: rpm
SPEEDMIN
Parameter of RAMP GENERATOR-function block. ( S4/16 )
Negative limit for speed reference.
1716 FB_P: I2 SC: SPEED HL: 0 LL: -30000 D: -20000 U: rpm
STARTSEL
Parameter of RAMP GENERATOR-function block. ( S4/16 )
Start-function when the motor is rotating
0 = START_FROM_0 (ramp output = 0 at start)
1 = FLYING_START (ramp output = actual speed at start.)
1717 FB_P: E2 SC: - HL: 1 LL: 0 D: 0 U: -
ACC_COMP.MODE
Parameter of RAMP GENERATOR-function block. ( S4/16 )
Acceleration compensation function
0 = DISABLED
1 = ENABLED.
1718 FB_P: E2 SC: - HL: 1 LL: 0 D: 0 U: -
ACC_COMP.TRMIN
Parameter of RAMP GENERATOR-function block. ( S4/16 )
The time in which the drive will accelerate from zero speed to the maximum speed using
nominal torque (T
N
) of the motor.
1719 FB_P: I2 SC: 0.1 HL: 32767 LL: 0 D: 0 U: s
RAMP.[SPEED_SET]
Input of RAMP GENERATOR-function block. ( S4/16 )
Set ramp output to this input with signal RAMP.[FOLL_ACT] (1705)
1720 FB_I: C4 SC: SPEED HL: 19999 LL: 0 D: 12102 U: -