EasyManuals Logo
Home>ABB>Industrial Equipment>HT604133

ABB HT604133 User Manual

ABB HT604133
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Operation Manual / A130-H.. - A140-H..
4 Commissioning / 4.3 Commissioning after taking out of operation
© Copyright 2021 ABB. All rights reserved. HZTL4030_EN Rev.G July 2021
4.3 Commissioning after taking out of operation
If present
u Remove cover plates (blind flanges) from the compressor casing, the gas inlet and the
gas outlet.
u Water-cooled version: Remove the screw plugs on the water connections and fit the water
pipe.
Version with compressor wheel cooling:
u Remove the screw plug on the cooling air connection and fit the cooling air line.
General
u Check the exhaust gas pipe before and after the turbine for combustion residues or wa-
ter residues and clean it. Remove any foreign objects that may be present.
u Check and clean filter silencer or air supply line, and remove any foreign objects that may
be present.
u Put engine-side oil circulation to the turbocharger into operation.
u Prepare the turbocharger for operation (see Checks before commissioning 42).
u The turbocharger is now ready for operation.
Page 44 / 122

Table of Contents

Other manuals for ABB HT604133

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HT604133 and is the answer not in the manual?

ABB HT604133 Specifications

General IconGeneral
BrandABB
ModelHT604133
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals