EasyManuals Logo
Home>ABB>Industrial Equipment>HT604133

ABB HT604133 User Manual

ABB HT604133
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Operation Manual / A130-H.. - A140-H..
8 Eliminating malfunctions / 8.4 Malfunctions when stopping
© Copyright 2021 ABB. All rights reserved. HZTL4030_EN Rev.G July 2021
8.4 Malfunctions when stopping
Runout noises
Possible causes Remedy
Turbochar-
ger
Turbocharger contaminated Clean (see chapter Periodic maintenance work
60)
Bearing damaged Check clearances (see chapter Measuring clear-
ance A and B). If clearances are outside the toler-
ance or if in doubt, contact an ABB Turbocharging
Service Station.
Rotor rubbing Check clearances (see chapter Radial clearances N
and R). If clearances are outside the tolerance or if
in doubt, contact an ABB Turbocharging Service
Station.
Foreign object in the tur-
bocharger
Dismantle turbocharger (see chapter Dismantling
and fitting 78). In case of damage, replace the
corresponding parts or contact an ABB Turbochar-
ging Service Station.
Table27: Malfunctions when stopping – Runout noises
Runout time too short
The runout time must be noted down as a reference. Because the runout time depends on
the oil viscosity, the runout time must always be measured at the same oil temperature.
If the runout time is significantly shorter in comparison to a previous measurement, the fol-
lowing table must be observed.
Possible causes Remedy
Turbochar-
ger
Turbocharger contaminated Clean (see chapter Periodic maintenance work
60)
Bearing damaged Check clearances (see chapter Measuring clear-
ance A and B). If clearances are outside the toler-
ance or if in doubt, contact an ABB Turbocharging
Service Station.
Rotor rubbing Check clearances (see chapter Radial clearances N
and R). If clearances are outside the tolerance or if
in doubt, contact an ABB Turbocharging Service
Station.
Foreign object in the tur-
bocharger
Dismantle turbocharger (see chapter Dismantling
and fitting 78). In case of damage, replace the
corresponding parts or contact an ABB Turbochar-
ging Service Station.
Table28: Malfunctions when stopping – Runout time too short
Page 76 / 122

Table of Contents

Other manuals for ABB HT604133

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HT604133 and is the answer not in the manual?

ABB HT604133 Specifications

General IconGeneral
BrandABB
ModelHT604133
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals