5 Operation and service / 5.4 Stopping the engine
© Copyright 2020 ABB. All rights reserved. HZTL4030_EN Rev.F February 2020
5.4 Stopping the engine
CAUTION
Residual heat in the turbocharger
If the residual heat in the turbocharger is not adequately dissipated, it may
damage the engine.
u Adequate cooling of the turbocharger must be ensured after stopping
the engine.
Water-cooled turbocharger variant
u Post-lubricate as long as the rotor is turning.
u Observe the oil pressure while performing post-lubrication: 0.5 <p
oil
≤1.0.
u Switch off post-lubrication as soon as the rotor is stationary or after no more than two
minutes.
Deviating procedures must be coordinated with ABB Turbo Systems.