Axis-4 sealing assembly tool set:
3HAC049699-001
xx1400000436
Fit the circular part of the radial sealing
assembly tool against the radial sealing.
6
Fit the tool plate to the other side of the
housing extender unit with the six screws
M6X50.
7
xx1400000437
Screw the screws, little by little, to press
the sealing into place.
8
Remove the assembly tool.9
Check that the sealing is undamaged and
properly fitted.
10
Refit both the axis-4 mechanical stop and
the axis-4 FPC unit to the housing extender
unit.
11
Refitting the axis-4 FPC unit
NoteAction
For robots with protection type Clean
Room
1
For robots with food grade lubrication
For robots with protection type Hygienic
Clean the joints that have been opened and
wipe the parts free from particles with
spirit on a lint free.