1.6.3 Brake testing
When to test
During operation, the holding brake of each axis normally wears down. A test can
be performed to determine whether the brake can still perform its function.
How to test
The function of the holding brake of each axis motor may be verified as described
below:
1 Run each axis to a position where the combined weight of the manipulator
and any load is maximized (maximum static load).
2 Switch the motor to the MOTORS OFF.
3 Inspect and verify that the axis maintains its position.
If the manipulator does not change position as the motors are switched off,
then the brake function is adequate.
Note
It is recommended to run the service routine BrakeCheck as part of the regular
maintenance, see the operating manual for the robot controller.
For robots with the option SafeMove, the Cyclic Brake Check routine is
recommended. See the manual for SafeMove in References on page 10.
38 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
1 Safety
1.6.3 Brake testing

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB IRB 1200-7/0.7 and is the answer not in the manual?

ABB IRB 1200-7/0.7 Specifications

General IconGeneral
BrandABB
ModelIRB 1200-7/0.7
CategoryRobotics
LanguageEnglish

Related product manuals