NoteAction
CAUTION
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of the robot! See Cut the paint or surface
on the robot before replacing parts on
page 158.
4
xx1300002400
Remove the lower arm cable housing cov-
er.
5
Disconnecting the cabling in the lower arm
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section The unit is sensitive to ESD on page 64
2
Continues on next page
294 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.3.4 Replacing the EIB/SMB unit
Continued