Loading...
Separating the tilt unit from the tubular
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 158.
2
xx1400000774
Remove the cable housing of the tubular by first
removing the screws.
Note
For robots with protection class IP67
For robots with protection type Foundry Plus
For robots with protection type Hygienic
The frame is glued and needs to be pried off.
3
xx1300002469
Support the weight of the tilt unit and remove the
screws.
4
Guide pin for tilt unit (axis 5):
3HAC049706-001
Fit guide pins to the gearbox.5
Always use three guide pins togeth-
er!
xx1400000775