xx1400000334
Remove the axis-3 radial sealing.4
Removing the axis-3 sealing ring
Use this procedure if the axis-3 sealing ring is to be removed.
NoteAction
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
CAUTION
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of the robot! See Cut the paint or surface
on the robot before replacing parts on
page 158.
2
Continues on next page
432 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the axis-3 radial sealing and sealing ring
Continued

Table of Contents