3 Maintenance
3.3.14. Inspection, UL-lamp
1893HAC022033-001 Revision: K
© Copyright 2004-2011 ABB. All rights reserved.
3.3.14. Inspection, UL-lamp
Location of UL-lamp
The UL-lamp is located as shown in figure below. Notice that the location can vary depending
on how the customer harness for axes 4-6 is mounted.
xx0200000117
Required equipment
A UL signal lamp
B Warning sign
C Warning label
D Position for cable gland
Equipment, etc. Spare part no. Note
Signal lamp 3HAC10830-1 To be replaced in case of detected
damage.
Includes UL signal lamp, 3HAC
13097-1, Warning label, 3HAC 4431-
1, Warning sign, 3HAC 1589-1
Standard toolkit - Content is defined in section Standard
toolkit on page 427.
Other tools and procedures may
be required. See references to
these procedures in the step-by-
step instructions below.
These procedures include references
to the tools required.