EasyManua.ls Logo

ABB MagMaster - A1.4 Setup for Psion Organiser; Lz64); A1.4.1 Keyboard Designations (Psion Organiser II)14

ABB MagMaster
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
A1.4 Setup for Psion Organiser II (CM, XP, LZ, LZ64)
Note. It is recommended that the mains adapter is used to power the Organiser where possible.
1. Connect the Psion Organiser Communications Link Adapter to the MagMaster Transmitter using a suitable adapter lead
consisting of a 25-pin D-Type plug to 9-pin D-Type socket (available as a Psion accessory).
2. Scroll through the following list of items which will be shown on the screen in the Comms
SETUP mode.
BAUD 4800
PARITY NONE
BITS 8
STOP 1
HAND NONE
PROTOCOL NONE
ECHO HOST
WIDTH NONE
TIMEOUT NONE
REOL <CR><LF>
REOF NONE
RTRN NONE
TEOL <CR>
TEOF NONE
TTRN NONE
Enter the following numbers to give the operations shown in the above:
13,10 <CR><LF>
13 <CR>
Select
TERM from the Comms menu to allow communication with the MagMaster Transmitter.
Set
COMMS to No Handshaking, No translations.
Set the MagMaster Display Mode (Parameter 21) to 1. (Refer to
3.6 Changing the Value of a Parameter in this manual).
A1.4.1 Keyboard Designations (Psion Organiser II)
Note. The and keys cannot be used, as these enable and disable the Organiser data output. Consult the Psion
Organiser handbook for further information.
A
DEL
EXE
ESC
Function Key
+
DEL
…APPENDIX A

Other manuals for ABB MagMaster