Table: Technical Data PVI-5000-TL-OUTD PVI-6000-TL-OUTD
Operating performance
Maximum Efciency (ηmax) 97.0%
Weighted Efciency (EURO/CEC) 96.4% / -
Power Supply Threshold 10.0 W
Stand-by Consumption < 8.0 W
Communication
Wired Local Monitoring (opt.) PVI-USB-RS232_485 (opt.)
Remote Monitoring (opt.)
VSN300 Wi Logger Card
(3)
(opt.), PVI-AEC-EVO (opt.),
VSN700 Data Logger (opt.)
Wireless Local Monitoring (opt.) VSN300 Wi Logger Card
(3)
(opt.)
User Interface LCD Display with 16 characters x 2 line
Environmental
Ambient temperature
-25...+60°C
-13...140°F
with derating above 60°C / 140°F
-25...+60°C
-13...140°F
with derating above 50°C / 131°F
Storage temperature -40...80°C (-40...+176°F)
Relative Humidity 0...100% condensing
Noise Emission < 50 db(A) @ 1 m
Maximum operating altitude 2000 m / 6560 ft
External environment pollution rating 3
Environmental Category External
Physical
Environmental Protection Rating IP 65
Cooling System Natural
Overvoltage rating as per IEC 62109-1 II (DC input) III (AC output)
Dimensions (H x W x D) 810mm x 325mm x 222mm / 31.9” x 12.8” x 8.7”
Weight < 26 kg / 57.3 lb
Assembly System Wall bracket
Safety
Safety class I
Insulation level Without transformer (TL)
Marking CE (50Hz only)
Safety and EMC Standards
EN62109-1, EN62109-2, AS/NZS3100, AS/NZS 60950, EN61000-6-1,
EN61000-6-3, EN61000-3-11, EN61000-3-12
Grid Standard
CEI 0-21, VDE 0126-1-1,
G59/3, EN 50438 (not for
all national appendices),
RD1699, AS 4777, C10/11,
IEC 61727, ABNT NBR 16149,
CLC/FprTS 50549, PEA, MEA
CEI 0-21, VDE 0126-1-1,
G59/3, EN 50438 (not for
all national appendices),
RD1699, AS 4777, C10/11,
IEC 61727, ABNT NBR 16149,
CLC/FprTS 50549
1. The output voltage range may vary according to the grid standard of the country of installation
2. The output frequency range may vary according to the grid standard of the country of installation
3. Check availability before to order
4. 4600W for Australia
Note. Features not specically mentioned in this data sheet are not included in the product