ABB | SACE Tmax XT
Interface and menus | 4 - Menu31 | © 2019 ABB | 1SDH002039A1002 - ECN000093027 - Rev. A
Advanced menus
The Advanced menu can be used to configure the following protections
(1)
:
Name Parameters SW package Page
MCR List in dedicated chapter
Standard Protections
45
2I List in dedicated chapter 46
IU List in dedicated chapter 47
UV
(2)
List in dedicated chapter
Voltage protections
50
OV
(2)
List in dedicated chapter 51
UV2
(2)
List in dedicated chapter 51
OV2
(2)
List in dedicated chapter 52
VU
(2)
List in dedicated chapter 52
S(V)
(2)
List in dedicated chapter
Voltage Advanced protections
53
S2(V)
(2)
List in dedicated chapter 54
RV
(2)
List in dedicated chapter 56
UF
(2)
List in dedicated chapter
Frequency protections
57
OF
(2)
List in dedicated chapter 58
UF2
(2)
List in dedicated chapter 58
OF2
(2)
List in dedicated chapter 59
RP
(2)
List in dedicated chapter
Power protections
60
D
(2)
List in dedicated chapter 61
RQ
(2)
List in dedicated chapter 64
OQ
(2)
List in dedicated chapter 63
UP
(2)
List in dedicated chapter 64
OP
(2)
List in dedicated chapter 63
ROCOF
(2)
List in dedicated chapter ROCOF protections 66
R STALL
(2)
List in dedicated chapter
Motor protections
69
R JAM
(2)
List in dedicated chapter 69
UC
(2)
List in dedicated chapter 70
U
(2)
List in dedicated chapter 70
PTC
(2)
List in dedicated chapter 71
V DIR, VINV
(2)
List in dedicated chapter
Interface protections (IPS)
125
59 S1
(2)
List in dedicated chapter 125
Warnings
VS Warning, FS Warning, FW1
Warning
125
Signallings
Threshold 1 I1, Threshold 2 I1,
Threshold Iw1, Threshold Iw2,
Phase Sequence
(2)
, CosØ
(3)
Standard Protections
79
Functions
External Trip, Trip Reset, Switch
On SET B
(4)
79
Synchrocheck List in dedicated chapter
(5)
76
(1)
if the Adaptive Protections package is available and Dual set has been activated, an intermediate menu
where the set can be selected (Set A / Set B) will be available before the list of protections (page 67); The only
menu always present via Advanced is Functions
(2)
available if provided for by Trip unit model or if the relative SW package has been activated, where possible
(page 6)
(3)
CosØ available if provided for by Trip unit model or if the Power Protections package has been activated
(4)
SET B available when Adaptive Protections package is present
(5)
available when Ekip Synchrocheck is present

Table of Contents