EasyManua.ls Logo

ABB TPL65VA33 - 9 Taking out of Operation at Short Notice; Possibilities for Emergency Repair

ABB TPL65VA33
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / TPL65VA32/33
Taking out of operation at short notice
9
Possibilities for emergency repair
9.1
Page 101
© Copyright 2015 ABB. All rights reserved.
September 2015 HZTL2464_EN Revision C
Taking out of operation at short notice
Possibilities for emergency repair
9.1
WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can cause severe personal
injury or fatal accidents can result.
Cordon off danger area.
Sound an alarm and depending on the situation, stop the engine.
Seal oil leaks.
Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves against thermal risks.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-
compliance with the directives for locking/blanking off the turbocharger
on the engine.
Follow the directives of the enginebuilder.
If the diesel engine must be capable of operation again as soon as
possible after damage to the turbocharger (emergency repair), the
following possibilities are available:
Fitting cover plate
Shutting off inlets and outlets
Bypass around turbocharger
9
9.1

Table of Contents