Operation Manual / TPL65VA32/33
Installing cartridge group
Page 97
© Copyright 2015 ABB. All rights reserved.
September 2015 HZTL2464_EN Revision C
Measure and note the axial clearance (
) (see the section on axial
clearance).
Clearances out of tolerance
Clearances out of tolerance and excessively worn components can be
the cause of serious damage to machinery and property.
Have components assessed and, if necessary, replaced by an ABB
Turbocharging Service Station.
Connect oil pipes and all air lines in accordance with engine builder’s
instructions.
Version with compressor wheel cooling system
Fit the air supply line. (Also see the chapter Preliminary remarks /
Layout and functioning.)
Fit the filter silencer or air suction branch.
Fit the insulation.