If the turbocharger is damaged and the engine can be shut down for only
a short time for emergency repairs, proceed as follows:
Fit the cover plate.
CAUTION
Always heed precisely the engine builder's instructions in case of en-
gine operation with a blocked / throttled turbocharger!
Dismantling the turbocharger
Dismantle the turbocharger (see the section Dismantling and fitting the
turbocharger).
Do not dismantle the nozzle ring.