TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. I 65
Easy Setup
-Connection S2
Sensor connection type relevant for all Pt, Ni, Cu resistance thermometers
two-wire: Sensor connection type in two-wire technology
three-wire: Sensor connection type in three-wire technology
• four-wire: Sensor connection type in four-wire technology
-wire Resistance S2
Sensor line resistance relevant for all Pt, Ni, Cu resistance thermometers with a two
-wire circuit
Cold junction compensation for thermocouples:
Internal: Use of internal reference junction temperature of the transmitter when using thermal compensating cable.
External - fixed: Use of external fixed reference junction temperature of the transmitter when constant thermostat
temperature is used (can be set with external reference junction temperature 2).
None: no reference junction compensation (CJC)
• Sensor 1 Temperature: Use of Sensor 1 as reference junction temperature for Sensor 2
Relevant for external reference junction compensation, specification of constant external reference junction temperature.
-50 to 100 °C
-output Assignment
Input / output assignment selects the inputs that are
mapped to the current output
Sensor 1
Electr. Meas. S1
Temp. of Electronics
Difference (S1-S2)
Meanvalue
Sensor 2
Electr. Meas. S2
Redundancy
Selects the physical unit for the sensor measuring signal
Units: °C, °F, °R, K, mV, Ω, V, kΩ
Defines the value for 4 mA (adjustable)
Defines the value for 20 mA (adjustable)
Configurable τ 63% output signal damping value