IMPORTANT INFORMATION
4
Should a malfunction occur with your wallbox, please first read the sections regard-
ing 'Resolving errors' in the respective eMH3 instruction manual. Should the fault or
malfunction recur and still not be able to be resolved, please contact ABL technical
support.
Always contact ABL technical support if:
the housing has been damaged mechanically,
the housing cover has been removed or can no longer be closed or locked,
sufficient protection against splashing water and/or foreign objects is obviously no
longer evident,
there is functional or visible damage to the charging socket(s) or external charging
cable(s)
or the wallbox does not function properly or has been otherwise damaged.
DANGER!
Should you detect damage to the housing or a charging socket, you must
immediately discontinue installation or take the already installed wallbox
out of operation via the upstream
miniature circuit breaker(s) (in the fol-
lowing called MCB(s), see also “Glossary & Definitions” on page 20)
in
your domestic power supply and the RCCB: No further use of the wallbox
is permitted in this case! Please contact ABL technical support!
Notes regarding installation
Please observe the following instructions for the installation of your ABL Wallbox:
The device must always be connected to the protective earth conductor of your
electricity supply. The protective earth connection will be made and checked by the
installing contractor. After installation, only qualified specialist electrical contractors
may make changes.
At all times comply with local safety regulations for the country in which you operate
the wallbox.
For proper operation, the power supply for the wallbox must be protected in the do-
mestic power supply with suitable MCB(s) and RCCB.
To disconnect the wallbox completely from the electricity grid, the power supply must
be interrupted using the upstream MCB(s)/RCCB(s) and the internal RCCB.
Ensure that the rated voltage and rated current of the device comply with the pa-
rameters of your local electricity grid and that the rated output is not exceeded dur-
ing the charging procedure.
The wallbox should not be installed in areas of high pedestrian traffic. Installation
along thoroughfares and marked escape routes should be especially avoided.

Other manuals for ABL eMH3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABL eMH3 and is the answer not in the manual?

ABL eMH3 Specifications

General IconGeneral
CategoryBattery Charger
Connector TypeType 2
Number of Charging Points1
Protection RatingIP54
Charging Current32 A
Input Voltage400 V AC
Protection ClassI
Output Voltage400 V AC
Output Current32 A
Operating Temperature-25°C to +50°C
Cooling MethodNatural Convection
ModeleMH3
Protection FeaturesOvercurrent protection, overvoltage protection, short circuit protection
Charging Powerup to 22 kW