Do you have a question about the Ablerex KRONOS and is the answer not in the manual?
Key safety instructions for installation and operation.
Explanation of warning symbols used in the manual.
Notes on FCC compliance and warnings about radio interference.
Illustrates the internal components and signal flow of the UPS.
Diagram showing the front panel of the 10kVA UPS model.
Diagram showing the front panel of the 15-20kVA UPS models.
Diagram showing the front panel of the 30-40kVA UPS models.
Visual representation of the right side of the 10kVA UPS unit.
Visual representation of the right side of the 15-20kVA UPS units.
Visual representation of the right side of the 30-40kVA UPS units.
Detailed diagram of the rear panel connectors and components for the 10kVA UPS.
Detailed diagram of the rear panel connectors and components for the 15-20kVA UPS.
Detailed diagram of the rear panel connectors and components for the 30-40kVA UPS.
Shows the internal battery tray configuration for the 10kVA UPS.
Shows the internal battery tray configuration for the 15-20kVA UPS.
Illustrates the internal top view components, including SD card slot and jumpers.
Illustrates the internal top view components, including SD card slot and jumpers.
Illustrates the internal top view components, including SD card slot and jumpers.
Guidelines for optimal storage and operational environmental conditions for the UPS.
Steps to safely remove the UPS from its packaging and prepare for movement.
Instructions for forklift operation with UPS models and associated dimensions.
Procedures for removing the 10kVA UPS from its shipping pallet using rails.
Specifies dimensions for forklift operation with 15-20kVA and 30-40kVA UPS units.
Instructions on how to raise wheel brakes for moving the 10kVA and 15-20kVA UPS.
Steps to block wheel brakes to secure the 30-40kVA and 10kVA UPS units.
Instructions for securing the 15-20kVA and 30-40kVA UPS units using fasteners.
Specifies minimum clearance distances for airflow and maintenance around the UPS.
Diagrams showing the location of power terminals for 10kVA and 15-20kVA UPS.
Shows terminal layout for 30-40kVA UPS and a table of maximum current ratings.
Guidelines for selecting appropriate cable sizes for mains, bypass, and external battery connections.
Recommendations for selecting circuit breaker sizes based on UPS capacity and voltage.
Diagrams illustrating single input UPS configurations, with and without isolation transformers.
Diagrams showing dual input UPS configurations, with and without isolation transformers.
Illustrates parallel UPS configurations with separate batteries and notes on isolation transformers.
Diagram showing parallel UPS operation using a shared battery bank.
Guidelines for using common output transformers in parallel UPS configurations.
Details on the AC Power switch and Battery Start button for UPS operation.
Explains the UPS's dry contact outputs and input, including jumper settings.
Describes Communication Slots 1 & 2, temperature sensor, RS-232, and communication selector.
Details on USB port, parallel communication switches, LED indicators, EPO, backfeed protection, and MBP detector.
Instructions for setting the SW2 and SW3 switches for relay/SNMP cards and parallel communication.
Guidelines for connecting multiple UPS units in parallel for increased capacity and reliability.
Visual guide showing how parallel communication cables are connected between UPS units.
Diagram illustrating a basic 1+1 redundant parallel UPS system configuration.
Diagram showing an N+1 parallel UPS system configuration with external bypass switch.
Explains the Normal, Economy (ECO), and Converter modes of UPS operation.
Details Normal, Bypass, and Battery modes of online UPS operation.
Describes the procedure and precautions for manual bypass operation.
Overview of UPS startup procedures and shutdown process.
Step-by-step guide for starting the UPS in Normal Mode.
Instructions for starting the UPS when mains input power is unavailable.
Steps for safely shutting down the UPS, including immediate load-off.
Procedures for switching to bypass, maintenance bypass, and returning to normal mode.
Overview of the LCD touch panel interface and its display elements.
Explains how to access and use the UPS menu and its sub-menus.
Comprehensive table detailing all menu functions and their sub-menus.
Details on Management, Setting, Event Log, and Permission Setting menus.
Guide on how to enter the parameters page and modify UPS settings.
Table listing user-configurable UPS parameters, ranges, and default values.
Detailed breakdown of the mimic display elements and their meanings.
Description of the Dry Contact Card for output and input contacts.
Information on the RS-485 MODBUS communication card.
Details about the SNMP card for Ethernet network communication.
Information on the temperature sensor and parallel communication card for UPS systems.
Steps to export UPS unit information and settings to an SD card.
Procedure for exporting the UPS event log to an SD card.
Detailed technical specifications for UPS input, output, and bypass functions.
Specifications related to mechanical, environmental, and communication interfaces.
Lists various battery manufacturers, ratings, and flame ratings.
Continues the list of battery manufacturers, ratings, and flame ratings.