EasyManuals Logo

AC Infinity CONTROLLER 67 User Manual

AC Infinity CONTROLLER 67
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
PROGRAMMING
AUTO MODE (LOW HUMIDITY TRIGGER)
Pressing the up or down button sets the low
humidity trigger. The fans will activate if the probe’s
reading meets or falls below this threshold.
Once triggered, the fan will gradually ramp up to the
speed set in ON mode. If the probe’s reading rises
above this trigger point, the fans will gradually slow
down to a stop or at the speed set in OFF Mode.
You may set this trigger below the low humidity
trigger to create a range in which the fan is active.
TIMER TO ON MODE
In this mode, press the up or down button to set
a countdown time. Once the timer ends, the fans
will trigger to run at the speed set in ON Mode. If
there was a speed set in OFF Mode other than
zero, then the fans will run at that speed during the
countdown.
The countdown will begin if no buttons are pressed
for 5 seconds. The time left on the countdown is
shown on the display, in the section below the
current fan speed. Leaving the timer mode while
the countdown is running will pause it until you
return to this mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed
when triggered to turn off.
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed when
triggered to turn off.