EasyManuals Logo

AC Tech SM410 User Manual

AC Tech SM410
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
SM01P 28
14 PARAMETER MENU
NO. PARAMETER NAME RANGE OF ADJUSTMENT
FACTORY
DEFAULT
01 LINE VOLTAGE HIGH (01), LOW (02) HIGH (01)
02 CARRIER FREQUENCY 4kHz (01), 6 kHz (02), 8 kHz (03), 10 kHz (04) 6 kHz (02)
03 START METHOD
NORMAL (01), START ON POWER UP (02),
START WITH DC BRAKE (03),
AUTO RESTART WITH DC BRAKE (04),
FLYING RESTART 1 (05),
FLYING RESTART 2 (06),
FLYING RESTART 3 (07)
NORMAL (01)
04 STOP METHOD
COAST (01), COAST WITH DC BRAKE (02),
RAMP (03), RAMP WITH DC BRAKE (04)
COAST (01)
05
STANDARD SPEED
SOURCE
KEYPAD (01), PRESET #1 (02),
0-10 VDC (03), 4-20 mA (04)
KEYPAD (01)
06 RELAY OUTPUT
NONE (01), RUN (02), FAULT (03),
INVERSE FAULT (04), FAULT LOCKOUT (05),
AT SET SPEED (06), ABOVE PRESET #3 (07),
CURRENT LIMIT (08), AUTO SPEED (09),
REVERSE (10)
NONE (01)
10
TB-13A FUNCTION
SELECT
NONE (01), 0-10 VDC (02), 4-20 mA (03),
PRESET SPEED #1 (04),
START FORWARD (05),RUN REVERSE (06),
START REVERSE (07),
EXTERNAL FAULT (08),
INVERSE EXT FAULT (09),
AUXILIARY STOP (10),
ACCEL/DECEL #2 (11)
NONE (01)
11
TB-13B FUNCTION
SELECT
NONE (01), 0-10 VDC (02), 4-20 mA (03),
PRESET SPEED #2 (04), DECREASE FREQ (05),
START FORWARD (06), JOG FORWARD (07),
JOG REVERSE (08), EXTERNAL FAULT (09),
INVERSE EXT FAULT (10), AUX. STOP (11),
ACCEL/DECEL #2 (12), REMOTE KEYPAD (13)
NONE (01)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AC Tech SM410 and is the answer not in the manual?

AC Tech SM410 Specifications

General IconGeneral
BrandAC Tech
ModelSM410
CategoryDC Drives
LanguageEnglish

Related product manuals