Page 22 of 33 Copyright © Access-IS 2020
5.5 Development commands
5.5.1 Firmware and imager levels
The firmware levels identify the release and build of a unit. Send the command AISFWV? to obtain
this information. For example: SB 01.00.00 is a first generation LSR116.
To check the latest firmware version or to update firmware, contact support@access-is.com.
Table 6. Firmware and imager commands
Simulates read outcome.
Used in Interactive mode to
communicate to the user after the host
has checked the data.
Only applicable to Interactive mode and
Host mode.
0 – ‘Good Read’
1 – ‘Bad Read’
2 - Ignore (requires
version 1.0.21 of the
firmware)
Interactive mode option flag.
Only applicable to Interactive mode
(AISOMD2).
If this flag is set, then the TRIG
messages from the LSR116 are sent
only on media detect and media
removed, regardless of commands from
the host.
Changes the configuration back to its
default values.
Warning: This command resets
all parameters to their default
values, including any values specific to
your stored configuration.
Returns the version of the firmware.
Returns the firmware version of the
imager.
Returns the timestamp of the firmware
release.
Enables or disables barcode reading.
This command is stored in volatile
memory so will return to the default
setting on power cycle.
Include DLEs (Data Link Escape).
Sets a ‘No Read’ message, sent at
defined intervals.
0 - Off
1–60000 milliseconds
CTS is raised when a ‘Good Read’
output is received.
Hardware handshaking - requires the
CTS to be high.