Operation Trouble Indication/Diagnosis:
Warning Indication:
Preasure Sensor Warning Number Of Flashes between the 2 second pause
Tank pressure is not increasing after the ECU
turns the Compressor(s) ON.
Verify Compressor circuit wiring connections.
Check Compressor fuse F2.
Verify Compressor plumbing connections.
Check for Compressor relay failure.
Check for Compressor failure.
Check for Pressure Sensor failure.
Pressure Sensor is not reading.
Verify wiring to Pressure Sensor.
Check Pressure Sensor for failure.
2
4
In the unlikely case of a system component failure during operation, the Speed
“ ”, “ ”, & “ ” Indications will ash simultaneously and sequentially to
indicate the trouble codes outlined below.
NOTE: This is the ONLY time that all 3 of the Speed Selections will ash