Pressure Sensor Mounting:
Tank Pressure Sensor Mounting Considerations
• Mount the Pressure Sensor vertically with the threads aiming downward to avoid
moisture build up in the sensor.
• Mount the Sensor close to the ECU to connect the pre-terminated sensor
harness that is part of the Main ECU Harness.
Step-By-Step
1.) Coat the threads of the Sensor and any threaded tting or adapter used in the
air supply system with a thread sealer to help prevent air leaks. We recommend
a liquid thread sealer for best results but Teon tape will work also. We strongly
recommend an Anaerobic Thread Sealer such as Loctite’s (P/N: 565)
2.) After tightening the sensor wipe off the excess thread sealer.
Air Tank
Example 1:
Pressure Sensor Mounting.
(In the top of the tank)
!
WARNING: Optional compressor control require use of an AccuAir
Pressure Sensor. System cannot be connected to any other
brand of Pressure Sensor or Pressure Switch.