EVOLUTION ELECTRIC STEAMER
9
The Control/Keypad Board will send
a 24VAC signal to the Solid State
Relay(s); closing the Relay(s) (as long
as the Door Switch and the Chamber
Pressure Switch are closed).
The Solid State Relay(s) then pass
Line Voltage to the Cast Heater’s
Elements generating heat evenly over
the bottom of the steam chamber;
creating steam for cooking.
1.3 TEMPERATURE SENSOR RTD AND
CONTROL/KEYPAD BOARD
As the water temperature rises, the
RTD will provide a signal, based on
the resistance of the sensor, to the
Control/Keypad Board to provide a
digital temperature display.
Control Panel will show PRE (Preheat)
on initial start-up until the steam
chamber reaches 195°F, then COO
(Cook) will be displayed between 195°F
and 212°F.
The operating default mode on initial
PWR ON is COOK mode; which
automatically causes the steamer to
go to the normal operating boiling
point, which is 212°F at sea level.
In COOK mode, the 24VAC output
from the Control/Keypad Board is
continuously on, so that the unit’s
temperature is controlled by the
Chamber Pressure Switch, which
opens at 1/2 inch of water column or
higher.
In HOLD mode (HLD), the steamer’s
regulated temperature will change
to the HOLD temperature’s preset
value. The Control/Keypad Board
will regulate temperature via the
RTD input, based on the current
HOLD mode preset value. (This
value can be changed using the
program function on the Control/
Keyboard Control.)