4-4
P5270/P5270 Refresh
Condential
No Step Specication Procedure Photo
1 Frequency
and Track-
ing
Eliminate visual
wavy noise by
Rsync, Frequen-
cy or Tracking
selection.
- Test Signal :
1024x768@60Hz
- Test Pattern : General-1
- check and see if image
sharpness and focus
are well-performed.
- If not, re-adjust by the
following steps:
(1) Select “Frequency”
function to adjust
the total pixel number
of pixel clock in one
line period.
(2) Then, select
“Tracking” function
and use right or left
arrow key to adjust
the vgalue to
minimize video icker.
2 Boundary Horz. And Vert.
position of
video should be
adjustable to
be the screen
frame.
- Test Signal :
1024x768@60Hz
- Test Pattern : General
- Adjust Resync or
Frequency / Tracking /
H. Position / V. Position
to the inner of the screen.
4-5 Inspection Procedure