S1200
Condential
4-4
4-5 Test Inspection Procedure
Change parts/
Update
M/B FW Color Wheel Lamp Module Engine
Version Update v v
Color Wheel Index v v
Reset lamp hour v
OSD Reset v v
EDID v
Re-write Lamp
Hour Usage
v
Check ROD
Position and
Adjust
v
Reset Dafult
Language
v v
4-6 PC MODE
1. Frequency and tracking boundry
Procedure - Test equipment: video generator.
- Test signal: analog 1024 x 768@60Hz - Test Pat
Partern: general-1 or master
- Check and see if the image sharpness is performed.
- If not re-adjust by the following steps:
(1) Select "Frequency" function to adjust total pixel
number of pixel clock in one line period.
(2) Select "Tracking" and use right or left arrow
General-1