THE OMNIVERSA
Delivery of the OmniVersa
Upon receipt of your OmniVersa, inspect the shipping container and contents for any obvious or concealed damage.
All ACP products are packaged carefully, for rapid safe delivery. We guarantee delivery in perfect condition to the
postal or delivery services. However, any damage or loss incurred during transportation or delivery is the postal or
delivery company responsibility. If damage or loss to the product and/or container is obvious or suspected, appropriate
notation must be made on the signed freight bill at the time of delivery. All damage claims should be promptly filed
with the delivering carrier and must be initiated by the addressee where the package was to be delivered. Retain the
original shipping container and inserts for validation of damage claim or use at a later date.
Unpack and check all accessories. A list of enclosed accessories is provided with each unit to assist you in
identification of the type and number of accessories.
Note:
The purpose of this manual is to acquaint you with the OmniVersa operating features and functionality. Please read
the manual carefully before attempting to operate the OmniVersa. If questions remain unanswered, contact your ACP
sales representative or call 800-350-1100. Outside the USA call 1-775-685-4000.
Introduction
The OmniVersa is a Multi-Modality therapy system that integrates electrotherapy, ultrasound and combination
therapy into one system. The electrotherapy is equipped with two identical electrotherapy channels. The
electrotherapy channels can be used in combination (linked) or independent. A comprehensive set of current
waveforms is available, targeting both pain management and muscle stimulation applications. Protocol driven
operation is available, providing both factory and/or user defined sequences of treatment steps. Protocols can run on
linked or independent channels. With independent channels two different protocols can be performed
simultaneously.
The OmniVersa ultrasound therapy section provides two positions for attachment of an ultrasound applicator.
Depending on the device configuration ordered, the Omnisound
®
Professional comes with an applicator with a large
contact area, an applicator with a small contact area or with both applicators. The applicators can operate in
continuous or pulsed mode at an ultrasound frequency of 1 MHz or 3 MHz. Contact control suspends the
application of ultrasonic energy when acoustical contact with the treatment area becomes insufficient. The
applicators are suitable for underwater treatments.
The OmniVersa can be operated as a combination device, combining the functions of the OmniVersa and the
Omnisound Pro in a single device when the Omnisound transducers are added to the system. With the OmniVersa
the simultaneous application of ultrasound and electrotherapy (combination therapy) is also possible. The remaining
electrotherapy channel can then be used independently.
The OmniVersa is designed to provide Interferential Current Therapy (IFC), Medium Frequency Alternating Currents
(MFAC), Low Voltage Pulsed Current (LVPC), High Voltage Pulsed Current Therapy (HVPC), and Patterned
Electrical Neuromuscular Stimulation (PENS), which is a form of stimulation that replicates the correct firing patterns
of muscles (agonist and antagonist or reciprocal muscle pairs) in Triphasic (ballistic), biphasic (reciprocal), or
functional patterns.
In Interferential and MFAC modes two separate generators produce medium frequency (2000, to 10,000 Hz)
alternating current in continuous or burst modulated modes. Two isolated output circuits with independent intensity
controls are provided. The output of each circuit is easily determined in milliamps through the display screen. The
digital timer allows the operator to select the length of the total treatment time and to monitor the time remaining in
minutes.
The OmniVersa offers Full Field (Premodulated) Interferential Current Therapy. An interferential vector scanning
mode can be turned off or on for stationary or continuous movement of the interferential field.