ACT1000/2000 Operating Instructions Software Version 4.00-00
12
Installer Menu
1
Feature present on ACT1000 only
2
Feature present on ACT2000 only
* On ACT2000 you will first be required to select a door.
System Settings Operation PIN Only PIN’s alone are used to gain access
Learn Users 1-1/2000 may use random coded cards
Ext. Keypad
1
Use external ACT20 keypad
KPD Release
1
✔ Key is exit button.
Exit PIN’s Exit PIN’s may be used in PIN only mode
Second Door
1
Second (Auxiliary) door enabled on ACT1000
User Prevent access if the user limit is reached
Limiting
2
One-To-One Card numbers may be assigned to Users
1-1000/2000
Multiple Users may have multiple cards
Display Backlight Keypad backlight enabled
Keypad Beep Keypad beep enabled
Show Status Display current status of doors on LCD
Show Events Display events on LCD as they occur
Handshake Use handshake line when printing
Tech Bleep
2
Controller bleeps for technical fault
PIN Length Sets the length of user/group PIN codes.
Fire Doors Allows the definition of doors with fire override.
User Tracking
2
Perimeter Define Perimeter doors
Antipassback Define Antipassback doors
Tracking Reset Set time for auto-reset (auto-logout)
User Limits Set user limits A & B
Outputs
2
Door 1 Define door 1 output special functions
Door 2 Define door 2 output special functions
Door Settings* Operation Push Button Door release button enabled
Lock Saver Relay de-energized as door opens
Chime Buzzer sounds as door opens
Guest Button
on external keypad fires AUX/buzzer
Exit Always Timezones don’t apply to exit readers
Interlock Only one door may be open at any time.
Silent Confirmation tones disabled
Exit PIR Door stays open while Push Button closed
Failsafe Door relay is normally energised
Alarms Door Forced Buzzer o/p active if door forced
Door Ajar Buzzer o/p active if door left ajar
Duress Alarm Buzzer o/p activated by duress code
Door Open Buzzer o/p active while door open
Acc. Granted Buzzer o/p when access granted
Acc. Denied Buzzer o/p when access denied