© Adam Equipment Company 2004
10
The weight will be output to a printer or PC.
Remove the weight, allowing the scale to return to zero and
put a second weight on.
Press [Print], the display will show "ACC 2" followed by the
new total in the memory for 2 seconds before returning to
displaying the weight of the item on the scale.
Continue until all weights have been added.
To view the totals in memory press the [Print] key when the
scale is at zero. The display will show "ACC xx" (where xx” is
the total number of readings) and the total weight, before
returning to zero.
The total will also be printed via the RS-232 interface.
To clear the memory, press [Smpl] immediately after
pressing [Print].
5.0 PARAMETERS
The scale has 5 parameters that can be chosen by the user
to set the scale.
To set the parameters press the [Mode] key during self-
checking test.
After a few seconds, the display will show the first function
"F1 UNT".
To view the current settings of each parameter, press the
[Zero] key.
Press the [Zero] key again to cycle through the other
parameters along with their current settings. For example, if
oFFis displayed with the weighing unit Pounds, the user will
not be able to use this unit while weighing a sample.
Press [Mode] to change the settings of a particular
parameter. For example, to enable the weighing unit pounds
change the setting to “on” by pressing [Mode] now.
Use the [Print] key to leave a parameter unchanged.