© Adam Equipment Company 2004
11
The following parameters are available:
FUNCTION DESCRIPTION
F1 UNT
Sets the units to be used (See section 5.1)
g / ct / Lb / OZ / d / GN / OZt / dWt / MM / TL.T / TL.C /
TL.t /t / N /g2.
F2 EL
Sets the backlight (See section 5.2)
EL on: backlight always on
EL AU: backlight automatically turns on when a key is
pressed
EL oFF: backlight always off
F3 SEr
Sets the print parameters (See section 5.3)
F4 oFF
Sets the auto switch-off parameter (See section 5.4)
tECH
Pressing [Zero] will allow the user to enter the technical
parameters setting mode. It is recommended not to
proceed with the settings of these parameters as those
are set up at the factory.
5.1 SELECTING THE UNITS
When “F1Unt” is displayed, press the [Zero] key to view the
current settings of each unit.
Press [Zero] again to cycle through the other units along with
their current settings. For example, if “oFF” is displayed with
the weighing unit Carats, the user will not be able to use this
unit while weighing.
Press [Mode] to change the settings of a particular unit. For
example, to enable the weighing unit Carats, change the
setting to “on” by pressing [Mode] now.
Use the [Print] key to leave a parameter unchanged.
While weighing a sample, the display will show the weight
and the units of weight currently in use. To view the weight
in other units (which are enabled), press [Mode].
The following table shows different units which are available
to the user and the conversion factors for each.