NetVanta 5305 Hardware Installation Guide Option Modules
61200990L1-34N Copyright © 2010 ADTRAN, Inc. 21
3. OPTION MODULES
The NetVanta 5305 family currently offers three option modules to meet networking requirements:
• NetVanta T3 Wide Module (P/N 1200832L1) on page 22
• NetVanta HSSI Wide Module (P/N 1200934L1) on page 23
• NetVanta Octal T1/E1 Wide Module (P/N 1202843E1) on page 24
The following pages describe each module, providing individual card specifications and features. Refer to
Appendix A on page 33 for pinout information. Refer to Installing Modules on page 28 for more installation
instructions.
NetVanta 5305 System Controller Module (P/N 1200831L1)
The NetVanta 5305 uses a central system controller module to provide configuration for the system using the
AOS. The NetVanta 5305 System Controller module (shown in Figure 4) provides control interfaces for the
NetVanta 5305 system including a
CONSOLE port (DB-9) and two Ethernet interfaces (RJ-48). See Table A-2
on page 33 for the
CONSOLE connector pinouts, and Table A-1 on page 33 for the Ethernet connector pinouts.
A system controller module is required for all NetVanta 5305 systems.
Figure 4. NetVanta 5305 System Controller Module
Features and Specifications
Interfaces
• Console: EIA-232 (DB-9 female) for access to CLI and monitoring
• Ethernet: Two 10/100Base-T interfaces (RJ-48) for connection to the LAN
Compliance
• EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
• UL/CUL 60950
• EN 60950
• IEC 60950
• AS/NZS 60950
Environmental
• Operating Temperature: 0°C to 50°C
• Storage Temperature: -20°C to 70°C
• Relative Humidity: Up to 95 percent, noncondensing
Physical
• Dimensions: 11.63-inch W x 8.63-inch D