21
% of BLEED - The % of the post bleed time or other source time that you want the timer to run.
LIMIT TIMER - The limit timer is a safety feature that limits a single feed cycle to the amount of time set
regardless of the calculated post feed %.
SOURCE - Select between cond. bleed, another timer or digital input as the time source.
4.6 With Bleed Timer
LIMIT TIMER - This timer starts when the conductivity
󰀨
the limit time has been reached. The time can be set
in MM:SS.
4.7 28-Day Timer
Each 28-day timer has Program 1-4 for programming the various feed times. While the programming steps

WEEKS - The week(s) that the timer is to feed.
DAYS - The day(s) that the timer is to feed.
START - The time of day for the timer to start.
RUN - How long the timer is to run.
PREBLEED - How long the controller is to bleed down
before feeding in chemical. NOTE: The prebleed starts
at the START time programmed above.
MIN COND - The minimum conductivity that the unit will
prebleed down to.
FEED LOCK 
BLEED LOCK 
FLOW LOCK 





NOTE: ORP lock is only for systems with the ORP function. If interlocked the ORP set point will switch to

to a relay activated by the ORP setpoint/control function.
5. Customize


>SYSTEM 1 TIMER 1 CHANGE<
LIMIT TIME
>SYSTEM 1 TIMER 1 CHANGE<
WEEKS MIN COND
DAYS FEED LOCK
START TIME BLEED LOCK
RUN TIME FLOW LOCK
PREBLEED ORP LOCK
>CUSTOMIZE<
UNIT NAMES
RELAY NAMES NOTEPAD
SYSTEM 1 NAME pH INDEX
mA IN
RUN SCREEN

Other manuals for Advantage Controls MegatronXS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Advantage Controls MegatronXS and is the answer not in the manual?

Advantage Controls MegatronXS Specifications

General IconGeneral
BrandAdvantage Controls
ModelMegatronXS
CategoryController
LanguageEnglish

Related product manuals