Do you have a question about the Advantech Adam - 4051 and is the answer not in the manual?
Details on the 2-year product warranty and terms.
List of hardware and software needed to set up an ADAM network.
Basic steps for configuring and connecting ADAM modules.
Procedures for changing baud rate and checksum settings.
Description of ADAM-4011/4011D modules, including features and protection.
Specific details on the ADAM-4011D, including supported inputs and data formats.
Description of the ADAM-4012 module, including I/O, event counting, and alarm signaling.
Specific details on the ADAM-4012, including supported inputs and data formats.
Description of the ADAM-4013 RTD input module and its capabilities.
Description of the ADAM-4015 RTD input module, including features.
Description of the ADAM-4015T thermistor input module, including features.
Description of the ADAM-4016 module, including I/O, excitation voltage, and alarms.
Overview of ADAM-4017, 4017+, 4018, 4018M, 4018+ modules.
Description of the 8-channel analog input module with programmable ranges.
Features of the ADAM-4018M 8-channel analog input data logger.
Description of the ADAM-4017+ 8-channel differential analog input module.
Description of the ADAM-4018+ 8-channel thermocouple input module.
Details on channels, inputs, and data forwarding for ADAM-4017.
Jumper settings and watchdog timer function for ADAM-4017+.
Details on channels, inputs, and support protocols for ADAM-4018.
Details on channels, inputs, data formats, and storage capacity for ADAM-4018M.
Description of the ADAM-4019+ universal analog input module.
Description of the ADAM-4021 analog output module, including slew rate.
Description of the ADAM-4024 4-channel analog output module.
Description of the ADAM-4050 module, including channel counts and I/O types.
Description of the ADAM-4051 16-channel isolated digital input module.
Description of the ADAM-4052 8-channel isolated digital input module.
Description of the ADAM-4053 16-channel digital input module.
Description of the ADAM-4055 16-channel isolated digital I/O module.
Description of the ADAM-4056S 12-channel sink type isolated digital output module.
Description of the ADAM-4056SO 12-channel source type isolated digital output module.
Description of ADAM-4060/4068 relay output modules and their applications.
Description of the ADAM-4060 4-channel relay output module.
Description of the ADAM-4068 8-channel relay output module.
Description of the ADAM-4069 8-channel relay output module.
Description of ADAM-4080/4080D counter/frequency modules.
Details on channels, input frequency, modes, and protocols for ADAM-4080.
Description of ADAM-4080D modules with LED display features.
Command table for ADAM-4011 analog input modules.
Command table for ADAM-4011D analog input modules.
Command table for ADAM-4012 analog input modules.
Command table for ADAM-4013 analog input modules.
Command table for ADAM-4015 and ADAM-4015T modules.
Command table for ADAM-4016 analog input/output modules.
Command table for ADAM-4017 analog input modules.
Command table for ADAM-4017+ analog input modules.
Command table for ADAM-4018 analog input modules.
Command table for ADAM-4018+ analog input modules.
Command table for ADAM-4018M analog input data logger.
Command table for ADAM-4019+ universal analog input module.
Command table for ADAM-4021 analog output module.
Command table for ADAM-4024 analog output module.
Command table for ADAM-4050 digital I/O module.
Command table for ADAM-4051 digital input module.
Command table for ADAM-4052 digital input module.
Command table for ADAM-4053 digital input module.
Command table for ADAM-4055 digital I/O module.
Command table for ADAM-4056S digital output module.
Command table for ADAM-4056SO digital output module.
Command table for ADAM-4060/4068 relay output modules.
Command table for ADAM-4069 relay output module.
Command table for ADAM-4080 counter/frequency input module.
Command table for ADAM-4080D counter/frequency input module.
Command to set address, input range, baud rate, data format, checksum, etc.
Command to read analog input data from specified module channels.
Command to read analog input from a specific channel (N).
Command to calibrate analog input module for gain errors (Span Calibration).
Command to calibrate analog input module for offset errors.
Command to calibrate a specified channel for gain errors.
Command to calibrate a specified channel for offset errors.
Command to configure input type and range for a specified channel.
Command to set the communication watchdog timer (WDT) cycle time.
Command for internal self-calibration of analog input modules.
Command to set memory configuration for analog input data logger.
Command to set the operation mode (Start/Stop) of the analog input data logger.
Command to set high/low alarm limits for channels in data logger.
Command to read digital I/O and alarm state of analog input modules.
Command to set digital output values (ON/OFF) for ADAM-4011/4011D/4012/4016.
Command to enable alarm for counter 0 in Latching or Momentary mode.
Command to download high alarm limit value into addressed module.
Command to download low alarm limit value into addressed module.
Command to disable all alarm functions of addressed analog input module.
Command for trimming calibration of output voltage.
Command for zero calibration of output voltage.
Command for span calibration of output voltage.
Command to set address, range, baud rate, data format, checksum, slew rate.
Command to send a value to the analog output module.
Command to store start-up voltage/current output configuration.
Command to trim the output value of analog output module.
Command to configure address, baud rate, and checksum status for digital I/O modules.
Command to set address, mode, baud rate, checksum, gate time.
Command to set the maximum counter value for counter 0 or 1.
Commands to set alarm limit value for counter 0 or 1.
Calibration procedures for analog input modules.
Calibration procedures for analog output modules.
Overview of the ADAM-4000 utility software and its capabilities.
Configuring settings for ADAM modules via the utility software.
Step-by-step guide for installing and configuring ADAM-4000 modules.
Steps to configure ADAM-4000 modules for Modbus protocol.
Changing serial data protocol to Modbus using ADAM utility.