EasyManuals Logo

AGA DC5 User Manual

AGA DC5
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
30
NOTE: The regulator is set for N.G. or for propane put out of
action.
Use the front left-hand hotplate burner injector as the
pressure test point.
For Natural Gas manifold pressure is 1kPa (4” w.g.)
For L.P.G. (Propane X Only) manifold pressure 2.54kPa
(10” w.g.).
Access to the gas regulator is as follows:-
A. Remove pan supports and all control knobs.
B. Remove four chrome buttons and the four plate
retaining screws (2 each side).
C. Remove left hand and centre shroud from the
control panel to gain access to the xing screws.
Remove two screws from control panel (one from
left hand hole and one from centre hole). (Fig.
10.1).
D. Pull top plate forwards slightly and lift up at front.
Support top plate and disconnect wiring to the two
neons. Remove top plate.
E. Lay the top plate on its top face, suitably protected.
14. Pressure testing

Other manuals for AGA DC5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AGA DC5 and is the answer not in the manual?

AGA DC5 Specifications

General IconGeneral
BrandAGA
ModelDC5
CategoryRanges
LanguageEnglish

Related product manuals