NOTE: The regulator is set for N.G. or for propane put out of
action.
Use the front left-hand hotplate burner injector as the
pressure test point.
• For Natural Gas manifold pressure is 1kPa (4” w.g.)
• For L.P.G. (Propane X Only) manifold pressure 2.54kPa
(10” w.g.).
Access to the gas regulator is as follows:-
A. Remove pan supports and all control knobs.
B. Remove four chrome buttons and the four plate
retaining screws (2 each side).
C. Remove left hand and centre shroud from the
control panel to gain access to the xing screws.
Remove two screws from control panel (one from
left hand hole and one from centre hole). (Fig.
10.1).
D. Pull top plate forwards slightly and lift up at front.
Support top plate and disconnect wiring to the two
neons. Remove top plate.
E. Lay the top plate on its top face, suitably protected.
14. Pressure testing