Chapter 6 359
Using the STATus System
Using the Status Registers
Using the STATus System
The standard event status register contains the following bits:
Bit Description
0 A 1 in this bit position indicates that all pending operations were completed following
execution of the *OPC command.
1 This bit is always set to 0. (The instrument does not request control.)
2 A 1 in this bit position indicates that a query error has occurred. Query errors have SCPI
error numbers from
499 to 400.
3 A 1 in this bit position indicates that a device dependent error has occurred. Device
dependent errors have SCPI error numbers from
399 to 300 and 1 to 32767.
4 A 1 in this bit position indicates that an execution error has occurred. Execution errors
have SCPI error numbers from
299 to 200.
5 A 1 in this bit position indicates that a command error has occurred. Command errors
have SCPI error numbers from
199 to 100.
6 A 1 in this bit position indicates that the
LOCAL key has been pressed. This is true even if
the instrument is in local lockout mode.
7 A 1 in this bit position indicates that the instrument has been turned off and then on.

Table of Contents

Other manuals for Agilent Technologies E4445A

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4445A and is the answer not in the manual?

Agilent Technologies E4445A Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4445A
CategoryMeasuring Instruments
LanguageEnglish

Summary

2. Instrument Functions: A − L

Marker Functions

Manages markers for trace analysis: Normal, Delta, Span Pair, Off, Marker Trace, Readout.

MEASURE Functions

Displays measurement menu for transmitter power, ACP, OBW, and distortion measurements.

MODE and Mode Setup

Selects measurement mode and configures common settings across measurements.

Peak Search Functions

Places marker on highest peak and displays search menu with parameters like Threshold and Excursion.

Preset Functions

Provides actions for instrument state reset: User, Mode, Factory presets, and Save User Preset.

SPAN / X Scale Functions

Activates Span function and displays menu for Span, Span Zoom, Full Span, Zero Span, Last Span.

SWEEP Functions

Controls sweep time, mode (continuous/single), auto sweep time, and gate parameters.

5 Programming Fundamentals

SCPI Language Basics

Introduces SCPI programming language, keywords, syntax, and parameters.

Improving Measurement Speed

Provides tips to make programs run faster, such as turning off display updates and using binary format.

Using the LAN to Control the Instrument

Details on configuring and controlling the instrument using LAN, including FTP, Telnet, Socket LAN, SICL.

Programming in C Using the VTL

Provides basic information about programming in C language using Agilent VTL (VISA transition library).

6 Using the STATus System

Status System Commands

Lists IEEE (*) Commands and STATus Commands for instrument status monitoring.

Using the Status Registers

Explains the PSA instrument status registers, their hierarchy, and how to use them.

7 Menu Maps: Spectrum Analysis

AMPLITUDE Y Scale Key

Menu maps for AMPLITUDE Y Scale functions, covering Reference Level, Attenuation, Scale, Presel, Corrections.

Auto Couple Key

Menu maps for Auto Couple, covering Auto All, FFT & Sweep, Detector, Avg/VBW Type, ADC Dither/Ranging.

Marker Key

Accesses marker control menu: Normal, Delta, Delta Pair, Span Pair, Off, Marker Trace, Readout.

Peak Search Key

Places marker on highest peak and displays search menu with parameters like Threshold and Excursion.

Preset Key

Provides actions for instrument state reset: User, Mode, Factory presets, and Save User Preset.

Related product manuals