EasyManua.ls Logo

Agilent Technologies U1242B User Manual

Agilent Technologies U1242B
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Agilent Technologies
Agilent U1241B and
U1242B
Handheld Digital
Multimeters
User’s and Service Guide

Table of Contents

Other manuals for Agilent Technologies U1242B

Questions and Answers:

Agilent Technologies U1242B Specifications

General IconGeneral
BrandAgilent Technologies
ModelU1242B
CategoryMultimeter
LanguageEnglish

Summary

Safety Notices

CAUTION

Defines a hazard that can cause product damage or data loss.

WARNING

Defines a hazard that can cause personal injury or death.

Safety Symbols

Regulatory Markings

Waste Electrical and Electronic Equipment (WEEE) Directive

Information on disposal and compliance with WEEE directive.

General Safety Information

WARNING

Critical safety precautions to observe during operation, service, and repair.

Environment Conditions

CAUTION

Precautions for instrument operation regarding environmental conditions like temperature and humidity.

Safety and EMC Requirements

Lists safety and EMC certifications for the instrument.

Declaration of Conformity (DoC)

1 Getting Started

Introduction

Overview of the multimeter's key features and front panel operations.

Checking the Shipping Contents

List of standard and optional items included with the multimeter.

Front Panel and Tilt Stand Overview

Visual guide to the multimeter's front panel, components, and tilt stand.

Annunciator Display Guide

Explanation of the various symbols and indicators on the multimeter's display.

Keypad and Rotary Switch Functions

Identification and function of the multimeter's keypad and rotary switch.

Input Terminal Connections

Diagram and explanation of the multimeter's input terminals and their functions.

2 Features and Functions

Measuring Voltage

Step-by-step guide for measuring AC and DC voltage using the multimeter.

Measuring Current

Procedures for measuring DC and AC current, including ranges above and below 440 mA.

Measuring % Scale of 4 – 20 mA

How to perform percentage scale readings for 4-20 mA or 0-20 mA signals.

Measuring Frequency

Instructions for measuring AC and DC frequency with the multimeter.

Measuring Resistance and Continuity

Steps for measuring resistance and performing continuity tests, including beeper operation.

Testing Diodes

Procedure for testing diode forward bias and checking for continuity with the multimeter.

Measuring Capacitance

Guide on how to measure capacitance, including tips for large and small values.

Measuring Temperature

Instructions for measuring temperature using thermocouple probes, including precautions.

Measuring Harmonic Ratio (U1242B)

How to measure harmonic ratio for power quality analysis with the U1242B model.

Using Switch Counter

Instructions for using the switch counter function to detect open/close switch conditions.

MinMax Recording

How to use the MinMax function to record minimum, maximum, and average readings.

Data Hold and Refresh Hold

Using Data Hold to freeze readings and Refresh Hold for dynamic value updates.

Null (Relative) Function

How to use the Null function to subtract a stored value for accurate measurements.

Data Logging (U1242B)

Guide to manual and interval data logging features available on the U1242B model.

Scanning Temperature Measurement (U1242B)

How to perform sequential temperature scans (T1, T2, T1-T2) with the U1242B.

Checking Battery Capacity

How to check the multimeter's battery level and interpret the display.

Alerts and Warnings During Measurement

Information on overload, input, and other alerts or warnings provided by the multimeter.

3 Default Setting Configurations

Setting Configurations

Guide to accessing and changing various setup and default configuration settings.

4 Service and Maintenance

General Maintenance

Procedures for routine cleaning and upkeep of the multimeter to ensure proper function.

Battery Replacement

Step-by-step instructions for replacing the multimeter's batteries safely and correctly.

Fuse Replacement

Detailed guide on how to replace internal fuses, including safety precautions.

Troubleshooting

Common issues and their solutions, including a table of malfunctions and identifications.

Returning Instrument for Service

Instructions and recommendations for safely shipping the instrument for repair or replacement.

5 Performance Tests and Calibration

Calibration Overview

Introduction to the calibration process, including closed-case electronic calibration and interval recommendations.

Adjustment is Recommended

Guidance on when and why readjustment is recommended for optimal performance.

Recommended Test Equipment

List of test equipment required for performance verification and calibration procedures.

Basic Operating Test

How to perform a basic operability test to ensure the multimeter is functioning correctly.

Backlight and Display Tests

Procedures for testing the backlight function and verifying all display segments are operational.

Input Terminal Tests

Tests to verify the proper functioning of the A and µA/mA input terminals, including warning alerts.

Calibration Process

A step-by-step guide to performing the calibration procedure for the multimeter.

Test Considerations

Important recommendations and factors to consider for accurate performance verification and calibration.

Input Connections for Calibration

Guidance on setting up test connections for optimal performance during calibration.

Performance Verification Tests

Recommended tests to verify the multimeter's performance against specifications.

Calibration Security

How to manage calibration security codes to prevent unauthorized adjustments.

Using the Front Panel for Adjustments

Detailed steps for performing calibration adjustments using the multimeter's front panel interface.

Adjustment Considerations

Factors to consider before and during calibration adjustments for best results.

Valid Adjustment Input Values

Table listing the required input values for performing calibration adjustments.

Calibration Adjustments

Step-by-step procedure for making calibration adjustments for various functions.

Exiting Adjustment Mode

Instructions on how to properly exit the calibration adjustment mode and secure the multimeter.

Calibration Count

Information on how to view and record the multimeter's calibration count.

Calibration Errors

A list of error codes that may occur during calibration and their meanings.

6 Specifications and Characteristics

DC Specifications

Detailed DC measurement specifications including range, resolution, and accuracy.

AC Specifications

Detailed AC measurement specifications including range, resolution, and accuracy.

Resistance Specifications

Specifications for resistance measurements, including accuracy and test current.

Diode Check/Audible Continuity Test Specifications

Specifications for diode testing and continuity checks, including accuracy and test current.

Temperature Specifications

Specifications for temperature measurements, including thermocouple types, range, resolution, and accuracy.

Capacitance Specifications

Specifications for capacitance measurements, including range, resolution, and accuracy.

Harmonic Ratio Specifications

Specifications for harmonic ratio measurements, including range, frequency, and voltage.

Frequency Specifications

Specifications for frequency measurements, including range, accuracy, and sensitivity.

Operating Specifications

Details on the multimeter's measurement rates (times/second) for various functions.

General Characteristics

Overall characteristics including power supply, display, environment, safety, dimensions, and shock/vibration.

Weight

The weight of the multimeter with and without batteries.

Warranty

Information on the product warranty period and coverage details.

Related product manuals