Introduction
42
To replace a station (For stateless IPv6 Address)
Use flowchart to replace a station.
1. Set "Language."
"3. Language" P.95
2. Retrieve the setting data from the
station to be replaced.
"1.4. Download Settings From Station" P.83
2. Replace the station.
Note the MAC address of the station to be
replaced.
3. Replace the station.
Note the MAC address of the station to be replaced.
3. Change "IP addressing method" to
"Static IPv6" for the newly installed
station and configure an appropriate
"IPv6 Address."
To configure a station through a Web browser,
refer to Web Setting Manual for each station.
4. Change "IP addressing method" to
"Static IPv6" for the newly installed
station and configure an appropriate
"IPv6 Address."
To configure a station through a Web browser,
refer to Web Setting Manual for each station.
4. Replace the setting data.
* If the settings are modified after being restored,
those changes will not be reflected.
"4.3. Station Replacement" P.99
The station is restarted and IPv6 Address will be
automatically configured.
If IP Address fails to be automatically configured, it
will become "FDC2::7000." If this happens, cycle
power to the station, and then the IP Address will
be automatically reconfigured.
5. Replace the setting data.
"4.3. Station Replacement" P.99
The station is restarted and IPv6 Address will be
automatically configured.
If IP Address fails to be automatically configured, it
will become "FDC2::7000." If this happens, cycle
power to the station, and then the IP Address will
be automatically reconfigured.
6. Upload the setting data to all the
stations.
"1.5. Upload Settings To Station" P.85
5. Upload the setting data to all the
stations.
"1.5. Upload Settings To Station" P.85
7. Set "LANGUAGE" of the replaced
Master Station.
Refer to IX Master Station Operation Manual.
6. Set "LANGUAGE" of the replaced
Master Station.
Refer to IX Master Station Operation Manual.
8. Done. 7. Done.