14.2.7.3. Configure Alarm Action via SIP Message
To set up the SIP message action receiver on the same web interface. Enter
the SIP account to which you want to send the configured SIP message as
an action when the alarm is triggered.
14.2.7.4. Configure Alarm Action via SIP Call
To set up the call action, you can enter the SIP or IP number of the device to
be called as an action, then enable Alarm Siren for arming zone as needed.